您的位置:首页  /  产品展示  /  EEG Testing  /  EEG CMRR tester  /  EEG CMRR tester CMRR3.0E

EEG CMRR tester CMRR3.0E

EEG CMRR tester CMRR3.0E, combining accuracy, convenience and test automation all together.
Compliant with IEC80601-2-26:2019 and applicable for R&D, compliance and production run testing.

  • 产品型号:
  • 厂商性质:代理商
  • 更新时间:2023-12-04
  • 访  问  量:228
立即咨询

联系电话:

详细介绍

EEG CMRR tester CMRR3.0E, combining accuracy, convenience and test automation all together.

Compliant with IEC80601-2-26:2019 and applicable for R&D, compliance and production run testing.

OVERVIEW

  • Designed for EEG CMRR and system noise testing

  • Extreme shielding structure to avoid internal and external noise interference

  • Built-in calibrated sine wave generator and Vc voltage measuring circuit to assure output accuracy level

  • Exclusive shielding covers can be added for higher CMRR requirement

  • Touch screen maximizes the test efficiency in standalone operation

  • PC software operation allows to control and conduct test via mouse clicks

  • Optional Standard Assistant software pack simplifies the medical standard with test sequences, options, parameters and pass criterions

  • Software Development Kit (SDK) assists user to develop customized or automated test software with less efforts


SPECIFICATION

ItemsOptionsSpecifications

Supply voltage0.5 / 2.828 / 20 / 2 / (70.71) (Vrms)±1%*

CM point voltage1.414 / 10 / 1 / (35.355) (Vrms)±1% (0.25Vrms ±2%)

Frequency50 / 60 / 100 / 120 (Hz)±1%

Electrode with ImpedanceChange electrode via the touch screen of CMRR 3.0ENone / RA / LA / LL / V1 / V2 / V3 / V4 / V5 / V6 / ALL

Electrode without ImpedanceChange electrode via the touch screen of CMRR 3.0ERA / LA / LL / V1 / V2 / V3 / V4 / V5 / V6

Imbalance impedance, R10kΩ10kΩ ±1%

Imbalance impedance, C47nF47nF ± 5%

DC offsetInternal battery powered, can be added on RA / LA / LL / V1~V6150mV ± 1%

Up to 40hrs with intermittent use

100pF capacitorUse 11:1 (110MΩ:10MΩ) voltage divider to measure indirectly100pF ± 5%

EnvironmentIntended for normal laboratory environment. The selection of critical components is known to be stable in the range shown. The 110MΩ divider may be affected by high humidity in excess of 85%

15 - 30°C

10 - 75% RH


*Require to measure with the multimeter of higher accuracy.

EEG CMRR tester CMRR3.0E

638355577262310490914.jpg


留言询价

留言框

  • 产品:

  • 您的单位:

  • 您的姓名:

  • 联系电话:

  • 常用邮箱:

  • 省份:

  • 详细地址:

  • 补充说明:

  • 验证码:

    请输入计算结果(填写阿拉伯数字),如:三加四=7

C

CODE
关注我们
  • 联系电话:13671818969

  • 联系邮箱:lisa815@yeah.net

  • 公司地址:中国(上海)自由贸易试验区临港新片区老芦公路536号

Copyright © 2024 上海力孚同科技有限公司版权所有   备案号:   技术支持:化工仪器网

sitmap.xml   管理登陆